Toshiba Starter Kits Support

- TLCS-870/C Series (8bit) Starter Kits -

BMSKTOPASFM29(AND)

- Additional information -

02/06/2004
> When powering up the starter kit PCB, ensure the test switch is set to low.

- Updates -

> None.


BMSKTOPASFH47(AND)

- Additional information -

> None.

- Updates -

> Micropak (870C SE-47) ROM Monitor Update

> Micropak 870C SE-47 ROM Monitor Start-up Guide

Download

Download


BMSKTOPASFM48(AND)

- Additional information -

05/01/2005
> The schematic found inside the Operations Guide denotes R14 as 10K. However, R14 should be 470K.

- Updates -

> Micropak (870C SE-48) ROM Monitor Update

> Micropak 870C SE-48 ROM Monitor Start-up Guide

Download

Download


BMSKTOPAS86FS49(A)

- Additional information -

24/02/2005
Install the Micropak (870C SE-49) update below to remedy these issues:

1. Micropak was having problems with high COM port numbers, typically around COM10 and above. The problem would manifest itself when attempting to program the starter kit boards. The standard 4 COM ports COM1 – COM4, along with any USB emulating COM ports would be correctly displayed in the Program dialog box. However, when an actual programming operation was performed, Micropak would not be able to connect to the higher number COM ports. This problem should now be fixed.

2. In the Program dialog box, if one or more sections were excluded from download, and the Include ROM Monitor option was not selected, then programming would fail. This has now been corrected.

3. It is now possible to specify the baud rate at which Micropak communicates with the ROM Monitor. This has resulted in the Program Options dialog box being revised slightly and gaining the Application Baud Rate and FC Clock Frequency options. The existing Baud Rate option has also been renamed to Program Baud Rate and gained an extra 57600 baud option. Note that this option cannot be used with the starter kit boards, but is for use with other development boards that sport a microcontroller using an fc clock amenable to 57600 baud.

- Updates -

> Micropak (870C SE-49) Update

ENSURE Micropak 870C SE-49 is installed but NOT running when installing this update.

Download



- TLCS-900/L1 Series (16bit) Starter Kits -

BMSKTOPAS91FY22(A)

- Additional information -

> None.

- Updates -

> None.

 
Contact us | Copyright | Disclaimer | Privacy Statement
 

- TLCS-870/C Series (8bit) Starter Kits -

BMSKTOPASFM29(AND)

- Additional information -

02/06/2004
> When powering up the starter kit PCB, ensure the test switch is set to low.

- Updates -

> None.


BMSKTOPASFH47(AND)

- Additional information -

> None.

- Updates -

> Micropak (870C SE-47) ROM Monitor Update

> Micropak 870C SE-47 ROM Monitor Start-up Guide

Download

Download


BMSKTOPASFM48(AND)

- Additional information -

05/01/2005
> The schematic found inside the Operations Guide denotes R14 as 10K. However, R14 should be 470K.

- Updates -

> Micropak (870C SE-48) ROM Monitor Update

> Micropak 870C SE-48 ROM Monitor Start-up Guide

Download

Download


BMSKTOPAS86FS49(A)

- Additional information -

24/02/2005
Install the Micropak (870C SE-49) update below to remedy these issues:

1. Micropak was having problems with high COM port numbers, typically around COM10 and above. The problem would manifest itself when attempting to program the starter kit boards. The standard 4 COM ports COM1 – COM4, along with any USB emulating COM ports would be correctly displayed in the Program dialog box. However, when an actual programming operation was performed, Micropak would not be able to connect to the higher number COM ports. This problem should now be fixed.

2. In the Program dialog box, if one or more sections were excluded from download, and the Include ROM Monitor option was not selected, then programming would fail. This has now been corrected.

3. It is now possible to specify the baud rate at which Micropak communicates with the ROM Monitor. This has resulted in the Program Options dialog box being revised slightly and gaining the Application Baud Rate and FC Clock Frequency options. The existing Baud Rate option has also been renamed to Program Baud Rate and gained an extra 57600 baud option. Note that this option cannot be used with the starter kit boards, but is for use with other development boards that sport a microcontroller using an fc clock amenable to 57600 baud.

- Updates -

> Micropak (870C SE-49) Update

ENSURE Micropak 870C SE-49 is installed but NOT running when installing this update.

Download



- TLCS-900/L1 Series (16bit) Starter Kits -

BMSKTOPAS91FY22(A)

- Additional information -

> None.

- Updates -

> None.